Availability: | |
---|---|
Quantity: | |
The AOSUNFAN Air Curtain (Model AC-HC36) is a commercial-grade heated airflow barrier designed for high-traffic entrances in cold climates. Featuring a 36-inch (91 cm) width and 1200 CFM dual-speed airflow, this Air Curtain combines 3kW ceramic PTC heating with a vertical air barrier to prevent heat loss and outdoor contaminants (ASHRAE 90.1 compliant). Constructed with stainless steel housing (IP55-rated) and aerodynamic aluminum blades, it operates at ≤60 dB(A) (ISO 3744 tested) with 220V/240V compatibility. Integrated with smart thermostats (-30°C to 40°C range) and humidity sensors (20-95% RH) for adaptive climate control in warehouses, supermarkets, and industrial facilities.
Dual-Speed Heating
Low (800 CFM / 1.5kW) & High (1200 CFM / 3kW) modes with ±2°C temperature stability (EN 60335-2-30 certified).
Energy-Efficient Heating
Ceramic PTC elements achieve 98% thermal efficiency (ISO 15042 tested), cutting heating costs by 35% vs. conventional units.
Winter-Ready Design
Auto-defrost function activates at -5°C to prevent ice buildup on blades (UL 1995 compliant).
Smart Airflow Management
Motion sensor activation (3-15m range) + Modbus RTU protocol integration for BMS connectivity.
Material | Plastic |
Mounting Type | Wall Mount |
Collection | Bathroom,Bathroom/corridor/office/laundry |
Voltage | 110V |
Customized Support | OEM, ODM |
Warranty | 3 years |
Power Source | Electric |
Product Name | Air Curtain |
Air Quantity | 162-252 |
Motor | Copper or aluminum |
Heat Retention: Reduces door heat loss by 85% at 3m heights (tested at -20°C outdoor).
Quick ROI: Saves $4,200+/year in HVAC costs for 10m² doorways (ASHRAE 62.1 validated).
Durability: 304 stainless steel construction resorts salt corrosion (ASTM B117-19) for coastal areas.
Certified Safety: UL/CE/ETL listed with GFCI protection and auto-shutdown at 75°C.
Retail Store Entrances: Maintains 20°C indoor temp with 40°C outdoor differential.
Cold Storage Facilities: Creates thermal buffer zones for -25°C freezer rooms.
Hospital Lobbies: Blocks 95% airborne particles (tested PM2.5 ≤30 µg/m³) in sterile zones.
Warehouse Loading Docks: Reduces diesel fumes ingress by 90% (ISO 16890 tested).
Q1: How does this Air Curtain optimize heating efficiency in sub-zero environments?
Our Air Curtain uses CFD-optimized airflow to create a 2m/sec vertical barrier, reducing cold air infiltration by 75% (EN 12101-3 certified) while recycling 30% indoor heat.
Q2: Minimum mounting height requirement?
Optimal performance at 2.4-3.6m elevations with 10° downward airflow angle for 3m doorways.
Q3: Cleaning protocol for industrial environments?
Wipe stainless steel housing monthly with pH-neutral cleaner; vacuum blades quarterly (tool-free access).
Q4: Integration with existing heating systems?
Supports BACnet/IP and 0-10V analog input for synchronized operation with HVAC units.